02 Oct 03
Up

 

02 October 2003 Status at The Aquatic Hillcrest

Headline: Site Acceptance Testing in progress

The site team (Brad Ron and Bill) returned to find the radar had paused again overnight.  They are delving into the Vax to determine the cause of the problem.  This problem seems to recur after about an hour of running.  In parallel, other tests are proceeding.

Test 5A was completed.  The NTDS boards in the Vax were switched which allowed the radar to continue running for >4 hours.  The team left the radar to run 24 hours before beginning the 120 hour test again tomorrow.

The letter documenting arrangements for the loan agreement regarding the 5 boards on loan from the GAF was received in Syracuse, and it was officially acknowledged and agree to by the LM contracts office.  The signed letter was transmitted electronically to BWB offices, and Greg is carrying a hard copy back Saturday.  This should allow formal test signoff to proceed.

Greg obtained the labels, cable and printer ribbons to carry to the site Saturday.  The team requested the incorrect breaker part number.  Terry Moselle and his team are re-ordering the correct breaker, the GFCI, 2 disks for the RES, and canceling the order for the lubricant spray, which will be procured in country by Greg.


Punchlists:

Remaining Items to Perform at Radome:

  1. Re-attach Row N21-N26 cable and interlock cable - Bill
  2. Word 1 of the Platform Control Word is indicating an intermittent fault in the 1st LO.  The word is 040210 Octal and we are also seeing a red LO fault light on the A10 PE.
  3. Cable label application (when the correct labels arrive from Syracuse)
  4. Replace GFCI (when it arrives from Syracuse) - Bill
  5. Replace CB9 50A breaker when it arrives from GAF or Syracuse - Bill

Need to obtain locally in Germany:

  1. Silicone spray lubricant

Needed from Syracuse:

Item(s) Requested DHL Air Waybill Picked Up Elapsed Days Status
Torque Wrench 18 September 9453134390 9/25 01:48 12+ in Frankfurt Customs at EGL 9/30
Kor-Lite Batteries 18 September 9453134412 9/25 01:47 12+ in Frankfurt Customs at EGL 9/30
GFCI 15 September 9453134401 9/25 01:49 15+ Terry Moselle ordering 10/2
RF Switch 18 September 9453134434 9/26 17:14 12+ Shipment on hold in Brussels, wrong delivery
2nd LO Generator (11A19A6) 24 September EGL given to EGL in Frankfurt 24 September 6+ Received in NYC 29 Sep, to be sent to Guy Blasi
50A Circuit Breaker 27 September     3+ Terry Moselle ordering 10/2
3 Row Receivers 30 September   given to EGL in Frankfurt 30 September 0+ shipped to US 30 September via EGL
1 Noise Detector 30 September   given to EGL in Frankfurt 30 September 0+ shipped to US 30 September via EGL
Maxtor ProDrive disk drive for the RES 29 September       Terry Moselle ordering 10/2

Link to Record Run Status