14 Oct 03
Up

 

14 October 2003 Status at The Aquatic Hillcrest

Headline: Work Nearly Complete

Review of data taken overnight indicates the best time to perform false alarm testing is 0500.

Good news this morning is that the STS signal mysteriously returned overnight.  This was predicted.

Captain Mario Fromm arrived this morning and we finally met.  This man has sent us many parts to allow testing to proceed.  The last four weeks he has worked only for Lockheed Martin.

Norbert Demel brought in an assortment of nuts, bolts and clamps to use to redress some of the discrepancies (see below).  This may save us a trip to Fulda.

There are many people here this morning, the shelter room is abuzz.  Ron and Brad are trying to fix the laser printer, and succeed.

Olaf obtains signature on test 4A using last night's Sunstrobe data.  4a is now complete, leaving only 10A and 10B.

Bill, Olaf and Steffen go upstairs to replace the row 31 receiver with a GAF loan.  In addition, they will install a new cable in row 5, and perform INCO.  Miscellaneous being procured by Norbert and Brad.  Ron collecting data to support closure of tests 10A and 10B.

125A breaker delivered 1100.  Re-powering array to check replacement of row 31 receiver and row 5 cable.

125A breaker is the wrong part - it is a reconditioned part, and even though it is the correct part number, has no bundle of wires from the back for the sensing circuit.  Have re-ordered the part.  Fortunately the weak breaker continues to serve.

Many discussions today about P(d) and pass/fail of flight tests. Hubert Merkel arrived this afternoon and participated in strategy sessions for how to improve flight test data.

We meet again at 0430 tomorrow to collect more data.


Remaining Record Run Tests

Test

Status

10A P3

In Progress

10B P2

In Progress

4A

Signed.

All other tests and steps

Signed

 


Discrepancy Status

Date Area Issue Corrective Action Completion Date
29 Sep 2003 PE cabinet exciter cable 77D613071G2 W61)116/A16-B Glue cable 29 Sep 2003
29 Sep 2003 Frequency Synthesizer cable P247/A19A1J4  Glue cable 29 Sep 2003
29 Sep 2003 Unit 14 2 lights out  Replace 29 Sep 2003
29 Sep 2003 ITU not communicating yet with modem cabinets  Finish current effort 29 Sep 2003
29 Sep 2003 Row N21-N26 Cable SP1/11A1BAY5 loose  Re-mount cable and interlock 4 Oct 2003
11 Oct 2003 Antenna 2 SSR cables loose on top of antenna Attach cables to antenna 14 Oct 2003
11 Oct 2003 STS STS signal lost Re-establish, repair or replace 14 Oct 2003
11 Oct 2003 A6 weak CB3 transformer breaker Replace wrong part , reordered
11 Oct 2003 Pedestal 15 cap screws, nuts and spacers missing from guard rail Replace screws 14 Oct 2003
11 Oct 2003 Pedestal screws missing from top cover Replace screws 14 Oct 2003
29 Sep 2003 General GFCI needs to be replaced  Replace ordered 28 Sep
29 Sep 2003 General CB9 azimuth drive breaker sensing circuit  Replace to Depot ordered 28 Sep
29 Sep 2003 Pedestal temperature sensor in pedestal is source of minor oil leak Replace ordered 6 Oct
11 Oct 2003 Gear Box left gear box leaking oil? Further observations required  

Loan Board Status

Date Part # Current Serial # Source of Asset Description Reference Designator Serial # to be repaired Status
29 Sep 2003 7328731G2  C176  GAF Row Receiver  Row 14  D132 in Syracuse
29 Sep 2003 7328731G2  C264  GAF Row Receiver  Row 32  D67 in Syracuse
29 Sep 2003 7328731G2  D43  GAF Row Receiver  Row 18  D60 in Syracuse
14 Oct 2003 7328731G2  C210  GAF Row Receiver  Row 31  D57 TBR Syracuse 17 Oct
29 Sep 2003 7327050G1  03538-22  GAF Noise Detector  11A1A4  C50 in Syracuse
29 Sep 2003 77D608349G1  LB0014  GAF 2nd LO Generator  10A4A19A6  LB0008 in Syracuse
10 Oct 2003 117279  013 GAF SPU A1 Processor board  A13A01  002 TBD
10 Oct 2003 117297  009 GAF SPU A3 disk drive board  A13A03  001 TBD
12 Oct 2003 2D-3B565-01 1227 GAF NTDS board 11A6A02A06 D1088 TBD

Photos from today: